Boiler safety has a new benchmark.
The level limiters have been granted TÜV and EU type approvals according to EN 12952/EN 12953. These Directives state, among other things, the requirements made on limiting systems and equipment for steam boiler plants and (pressurized) hot water installations. The low-level limiter and high-level alarm system is certified acc. to IEC 61508 for the Safety Integrity Level 3 (SIL 3).
The safety parameters were checked and certified by TÜV Süd – proof of the system’s long-term durability without hazardous failures. The new limiter system NRS 1-50 / NRG 1x-50 is an advancement of the successful series NRG 1x-11 / NRS 1-7, which it will replace by the end of 2010. The new low-level limiter enables the interconnection of two low-level electrodes with one low-level limiter switch, thus fulfilling the requirement for two independently working low-level limiters.
Special features:
The safety parameters were checked and certified by TÃV Süd â proof of the systemâs long-term durability without hazardous failures. The new limiter system NRS 1-50 / NRG 1x-50 is an advancement of the successful series NRG 1x-11 / NRS 1-7, which it will replace by the end of 2010. The new low-level limiter enables the interconnection of two low-level electrodes with one low-level limiter switch, thus fulfilling the requirement for two independently working low-level limiters. Special features:
- Low-level limiter by interconnecting 2 low-level electrodes with one low level switch
- Automatic, cyclic and redundant self-monitoring
- Forcibly guided safety relays, dual processor
- Error diagnosis for rapid detection of malfunctions
- Instantaneous external signalling for each measurement channel
- Flexible assignment of the output safety circuit contacts support customization for national requirements
- Approved safety over the entire product lifetime
NRG 16-50
NRG 16-50NRG 16-51
NRG 16-51NRS 1-50 for one electrode
NRS 1-50 for one electrodeNRS 1-50 for two electrodes
NRS 1-50 for two electrodesNRS 1-51
NRS 1-51NRG 16-50
NRG 16-50NRG 16-51
NRG 16-51NRS 1-50 for one electrodes
NRS 1-50 for one electrodesNRS 1-50 for two electrodes
NRS 1-50 for two electrodesNRS 1-51
NRS 1-51EC type approval
EC type approvalSIL 3
SIL 3Type-approved level limiter
Type-approved level limiterSpecification: SPECTORmodul Self Monitoring High Level Alarm
Specification: SPECTORmodul Self Monitoring High Level AlarmSpecification: SPECTORmodul Low Water Level Limiter
Specification: SPECTORmodul Low Water Level LimiterContact our Valve Specialist Team:
Brendan Merrigan (External) – Mob: 087 2598124
Internal Team
Brian Barry – Tel: 021 461 7211
Darragh Rodgers- Tel: 021 461 7241
Miriam Adair- Tel: 021 461 7235
Ross O’Donovan – Tel: 021 461 7230
Shauna O’Connor – Tel: 021 461 7237
Tim Quigley – Tel: 021 461 7209
Vicki McGrath – Tel: 021 461 7207
Tel: 021 461 7200