High Pressure Steam Conditioning Valve DCE
Function
Pressure and temperature control
Application
High pressure turbine Bypass without safety function for starting up or stopping steam boilers, respectively
Steam transfer in case of turbine failure
Steam conditioning for process steam lines
Design
Construction: | angular/Z-form |
Seat-Ø: | 28- 200 mm |
Capacity: | K-values from 8 m3/h until 800 m3/h |
Injection: | secondary atomized steam injection or controlled pressure atomizing or spindle injection with atomized steam |
Throttling: | controlled/uncontrolled |
Actuator: | hydraulic, electrical or pneumatic |
Characteristic: | linear/equal percentage |
Body: | forged, materials and pipe connection in accordance with customer specification |
Leakage rate: | DIN 3230 part 3 – leakage rate 1 as well as ANSI/FCI 70-2 Class V possible |
Mounting position: | vertical, horizontal and hanging |
Contact our Valve Specialist Team:
Brendan Merrigan (External) – Mob: 087 2598124
Internal Team
Brian Barry – Tel: 021 461 7211
Darragh Rodgers- Tel: 021 461 7241
Miriam Adair- Tel: 021 461 7235
Ross O’Donovan – Tel: 021 461 7230
Shauna O’Connor – Tel: 021 461 7237
Tim Quigley – Tel: 021 461 7209
Vicki McGrath – Tel: 021 461 7207
Tel: 021 461 7200